| Test
Kit Hydrogen Sulfide |
| Model
HS-C Range |
| 0-5
mg/L, Color Chart |
 |
|
| Hydrogen
Sulfide - Resulting from the anaerobic |
|
decomposition of organic matter, hydrogen sulfide is |
|
present in many water supplies. |
| Sewage
and industrial wastes are other sources of |
| sulfide
pollution. Highly toxic, this compound has a |
| characteristic
rotten egg odor, which can be detected |
| long
before harmful concentrations are reached. |
|
|
| Test
Kit Manganese, |
| Model
MN-5, Range |
| 0-3
mg/L, Color Disc |
 |
|
| Our
unique color discs feature a continuous-gradient |
|
color wheel for fast, accurate comparisons. Simply |
|
rotate the color wheel to obtain a color match with |
| the
reacted sample. Typical accuracy is ± 10%, |
| subject
to individual color perception. |
|
|
| Test
Kit Hardness Total, |
| Model
5-B, Range 1-30 gpg, |
| Drop
Count Titration |
 |
|
| Our
economical drop count procedures provide a |
|
low-cost method for titrimetric determinations. To |
|
calculate concentration, simply add an indicator to |
|
the sample, then use the dropper to add titrant until |
|
the color changes. Typical accuracy is ± 1 drop
for |
| titrations
requiring up to 20 drops and ± 5% for |
| titrations
requiring over 20 drops. Most titrations |
| require
10 to 20 drops. |
|
|
| Test
Kits, Water Quality |
| MultiParameter
Kits, |
| Model
HA-95A |
 |
|
| Hardness
and Iron - Model HA-95A with Color Cube |
| Compact
and convenient for routine checks. |
|
|
| Test
Kits, Water Quality |
| MultiParameter
Kits, |
| Model
HA-62A |
 |
|
| Hardness,
Iron and pH - Model HA-62A includes |
|
color discs and color comparator for colorimetric |
|
comparison of iron and pH. |
|
|
| Test
Kit Tannin Lignin, |
| Model
TA-3 Range 0-15, |
| 0-150
mg/L, Color Disc |
 |
|
| Our
unique color discs feature a continuous-gradient |
|
color wheel for fast, accurate comparisons. Simply |
|
rotate the color wheel to obtain a color match with |
| the
reacted sample. Typical accuracy is ± 10%, |
| subject
to individual color perception. |
|
|
| Test
Kit Chlorine Free, |
| Model
Cube, Low |
| Range
0-2.5 mg/L |
 |
|
| Hach
color cubes combine a sample/mixing cell and a |
|
calibrated, stepped color comparator in a single molded |
|
plastic piece. Just mix premeasured reagent with |
|
sample in the cube and match the developed color to |
| one
of five calibrated steps. Typical accuracy is ±
|
| 20%,
subject to individual color perception. |
|
|
| Test
Kit Chlorine Total, |
| Model
Cube, |
| Low
Range 0-2.5 mg/L |
 |
|
| Hach
color cubes combine a sample/mixing cell and a |
|
calibrated, stepped color comparator in a single |
|
molded plastic piece. Just mix premeasured reagent |
|
with sample in the cube and match the developed color |
| to
one of five calibrated steps. Typical accuracy is ± |
| 20%,
subject to individual color perception. |
|
|
| Test
Kits, Chlorine Total, |
| Mid
and High Range 0.2-4 or |
| 1-20
mg/L, Model CN-65 |
 |
|
| Our
economical drop count procedures provide a |
|
low-cost method for titrimetric determinations. To |
|
calculate concentration, simply add an indicator to |
|
the sample, then use the dropper to add titrant until
|
|
the color changes. Typical accuracy is ± 1 drop
for |
| titrations
requiring up to 20 drops and ± 5% for |
| titrations
requiring over 20 drops. Most titrations |
| require
10 to 20 drops. |
|
|
| Test
Kit pH, Model 17F, |
| Mid
Range 5.5-8.5 pH, |
| Color
Disc |
 |
|
| Our
unique color discs feature a continuous-gradient |
|
color wheel for fast, accurate comparisons. Simply |
|
rotate the color wheel to obtain a color match with |
| the
reacted sample. Typical accuracy is ± 10%, |
| subject
to individual color perception. |
|
|
| Key
Dealer |
| Combo
Kit |
 |
|
| With
the Key Dealer Combo Kit you will receive 5 Kits |
|
in one. The Key Dealer Combo Kit includes the |
|
Manganese Test Kit (Model MN-5), Hydrogen Sulfide |
|
Test Kit (Model HS-C), Iron Test Kit, Hardness Iron |
| and
pH Test Kit (Model HA-62A) and the TDS Pocket |
| Pal. |
|
|
| Pocket
Pal pH or TDS Tester |
| (10-1990
TDS) |
 |
|
| Hach
Pocket Pal , Testers are easy to use, |
|
economical and reliable. Now IP67 rated (dustproof |
|
and waterproof), Pocket Pal Testers are immune to |
|
harsh environments and accidental spills that could |
| harm
electronics. If accidentally immersed in water, |
| the
circuitry will remain unharmed. Pocket Pal Testers |
| clip
onto your shirt pocket, produce immediate results, |
| and
feature an easy-to-read liquid crystal display |
| (LCD).
While not recommended as a replacement for a |
| pH
or ORP instrument/electrode system, or a Hach |
| Conductivity
or TDS meter, Pocket Pal
Testers offer a |
| cost
effective alternative for routine, on-the-spot |
| measurements. |
|
|
| Myron
L TDS Meter |
| (0-5000
ppm) |
 |
|
| Plant
health can be greatly affected by pH (acidic or |
|
basic), salinity (soluble salts), and alkalinity, yet
these |
|
factors are often ignored by growers. It is easy to test |
|
for these three important parameters using a portable |
| Myron
L AGRI-METER with Soil Test Kit. |
|
|
|